AIM:- to measure angular displacement by RVDT.
APPARATUS: - trainer kit, connecting leads.
THEORY: -
RVDT stands for rotary variable differential transformer .It same as LVDT expect that its core is cam shaped & may be rotated between the windings by a shaft.
At the null position of core output voltage of secondary windings S1 & S2 are equal and therefore net output is zero.
Any angular displacement from null position will result in a differential voltage output. Clockwise rotation produces an increasing voltage of a secondary winding of one phase while counter clockwise rotation produce an increasing voltage of opposite phase.
PROCEDURE:-
Connect the leads and switch on supply.
Give the angular displacement and read the output reading in voltage.
RESULT: -Thus we have measured the angular displacement using RVDT.